Energy Standards Equations | |
---|---|
Refrigerators and Refrigerator-Freezers with manual defrost | 16.3 AV+316 |
Refrigerator-Freezers—partial automatic defrost | 21.8 AV+429 |
Refrigerator-Freezers—automatic defrost with: | |
Top mounted freezer without ice | 23.5 AV+471 |
Side mounted freezer without ice | 27.7 AV+488 |
Bottom mounted freezer without ice | 27.7 AV+488 |
Top mounted freezer with through the door ice service | 26.4 AV+535 |
Side mounted freezer with through the door ice | 30.9 AV+547 |
Upright Freezers with: | |
Manual defrost | 10.9 AV+422 |
Automatic defrost | 16.0 AV+623 |
Chest Freezers and all other freezers | 14.8 AV+223 |
Product Class: | Ratio |
---|---|
Without Reverse Cycle and With Louvered Sides: | |
Less than 6,000 Btu | 8.0 |
6,000 to 7,999 Btu | 8.5 |
8,000 to 13,999 Btu | 9.0 |
14,000 to 19,999 Btu | 8.8 |
20,000 and more Btu | 8.2 |
Without Reverse Cycle and Without Louvered Sides: | |
Less than 6,000 Btu | 8.0 |
6,000 to 7,999 Btu | 8.5 |
8,000 to 13,999 Btu | 8.5 |
14,000 to 19,999 Btu | 8.5 |
20,000 and more Btu | 8.2 |
With Reverse Cycle and With Louvered Sides | 8.5 |
With Reverse Cycle, Without Louvered Sides | 8.0 |
(A) Gas Water Heater: | .62(.0019 x Rated Storage Volume in gallons) |
(B) Oil Water Heater: | .59(.0019 x Rated Storage Volume in gallons) |
(C) Electric Water Heater: | .95(.00132 x Rated Storage Volume in gallons) |
Wall | |
Fan type | |
Up to 42,000 Btu/hour | 73% AFUE |
Over 42,000 Btu/hour | 74% AFUE |
Gravity type | |
Up to 10,000 Btu/hour | 59% AFUE |
Over 10,000 Btu/hour up to 12,000 Btu/hour | 60% AFUE |
Over 12,000 Btu/hour up to 15,000 Btu/hour | 61% AFUE |
Over 15,000 Btu/hour up to 19,000 Btu/hour | 62% AFUE |
Over 19,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
Over 46,000 Btu/hour | 65% AFUE |
Floor | |
Up to 37,000 Btu/hour | 56% AFUE |
Over 37,000 Btu/hour | 57% AFUE |
Room | |
Up to 18,000 Btu/hour | 57% AFUE |
Over 18,000 Btu/hour up to 20,000 Btu/hour | 58% AFUE |
Over 20,000 Btu/hour up to 27,000 Btu/hour | 63% AFUE |
Over 27,000 Btu/hour up to 46,000 Btu/hour | 64% AFUE |
Over 46,000 Btu/hour | 65% AFUE |
Boiler Type | Minimum Annual Fuel Utilization Efficiency | Design Requirements |
---|---|---|
Gas Hot Water | 82% | No Constant Burning Pilot, Automatic Means for Adjusting Water Temperature |
Gas Steam | 80% | No Constant Burning Pilot |
Oil Hot Water | 84% | Automatic Means for Adjusting Temperature |
Oil Steam | 82% | None |
Electric Hot Water | None | Automatic Means for Adjusting Temperature |
Electric Steam | None | None |
Application for Operation of | Ballast Input Voltage | Total Nominal Lamp Watts | Ballast Efficacy Factor |
---|---|---|---|
one F40T12 lamp | 120 | 40 | 1.805 |
277 | 40 | 1.805 | |
two F40T12 lamps | 120 | 80 | 1.060 |
277 | 80 | 1.050 | |
two F96T12 lamps | 120 | 150 | 0.570 |
277 | 150 | 0.570 | |
two F96T12HO lamps | 120 | 220 | 0.390 |
277 | 220 | 0.390 |
Application for operation of | Ballast input voltage | Total nominal lamp watts | Ballast efficacy factor |
---|---|---|---|
One F34T12 lamp | 120/277 | 34 | 2.61 |
Two F34T12 lamps | 120/277 | 68 | 1.35 |
Two F96T12/ES lamps | 120/277 | 120 | 0.77 |
Two F96T12HO/ES lamps | 120/277 | 190 | 0.42. |
Lamp Type | Nominal Lamp Wattage | Minimum CRI | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
---|---|---|---|---|
4-foot medium bi-pin | 35 W | 69 | 75.0 | 36 |
35 W | 45 | 75.0 | 36 | |
2-foot U-shaped | 35 W | 69 | 68.0 | 36 |
35 W | 45 | 64.0 | 36 | |
8-foot slimline | 65 W | 69 | 80.0 | 18 |
65 W | 45 | 80.0 | 18 | |
8-foot high output | 100 W | 69 | 80.0 | 18 |
100 W | 45 | 80.0 | 18 |
Nominal Lamp Wattage | Minimum Average Lamp Efficacy (LPW) | Effective Date (Period of Months) |
---|---|---|
40–50 | 10.5 | 36 |
51–66 | 11.0 | 36 |
67–85 | 12.5 | 36 |
86–115 | 14.0 | 36 |
116–155 | 14.5 | 36 |
156–205 | 15.0 | 36 |
Lavatory faucets | 2.5 gallons per minute |
Lavatory replacement aerators | 2.5 gallons per minute |
Kitchen faucets | 2.5 gallons per minute |
Kitchen replacement aerators | 2.5 gallons per minute |
Metering faucets | 0.25 gallons per cycle |